Cray Sonexion 1300 Specifications
| Rack |
| Height |
42U or 1,867 mm (73.5 in) |
| Width |
600 mm (23.62 in) |
| Depth |
1,200 mm (47.24 in) |
| Rack Switches |
1 x 48-port Gigabit Ethernet, 2 x 36-port InfinBand QDR (40Gb/s) (18-port switch option) |
| Standard Cooling |
Passive |
| Water Cooled Option |
Rear Door Heat Exchange Unit |
| Weight (Standard Air-cooled) |
621 kg (1,368 lbs) |
| Weight (Water Cooled Door Wet) |
34.5 kg (76 lbs) additional |
| |
| Metadata Management Unit (MMU) |
| Base/Expansion Unit Height |
2U or 89 mm (3.5 in) |
| Base/Expansion Unit Drive Slots |
24 x 2.5 inch drives |
| Base Metadata Data Drives |
22 x 146GB 15K RPM, 450GB or 600GB, 10K RPM, SAS, RAID10 |
| Base Metadata Journal SSDs |
2 x 100GB, RAID1 |
| Expansion Data Drives |
24 x 600GB, 10K RPM SAS, RAID10 |
| Maximum Number of Files per File System |
6 billion |
| Scalable Storage Unit (SSU) |
| Base/Expansion Unit Height |
5U or 222.2 mm (8.75in) |
| Base/Expansion Unit Drive Slots |
84 x 3.5 inch drives |
| Base/Expansion Unit Data Drives |
82 x 1TB, 2TB or 3TB, 7.2K RPM NL-SAS, RAID6 |
| Base/Expansion Unit SSDs |
2 x 100GB, RAID1 |
| IOR Read Bandwidth |
3 GB/s |
| IOR Write Bandwidth |
3 GB/s |
| |
| System Availability |
| Hot Swappable |
Disk Drives, Power Supply Units, Fans, Power Cooling Modules, Metis Battery Unit, Server Modules |
| |
| Software & Support Information |
| Software |
CSSM, Linux and Lustre included, 1 year renewable |
| Hardware |
1 year renewable |
General System Environmental Specifications
| Altitude and Temperatures |
| Operational Altitude |
-30 to 3048m (-100 to 10,000ft) |
| Operating Temperature Range |
5-35° C |
| Temperature Variance |
De-rated by 1° C/300m above 900m below the specified maximum temperature |
| Humidity |
20% to 80% non-condensing |
| |
| Power Options Per Rack |
| US |
208V AC 24A, 3 Phase delta, 6 Circuit/Rack, NEMA L21-30P |
| EMEA |
415V AC 32A, 3+N+E Phases, 4 Circuit/Rack, IEC60309 32A |
| Peak Power Consumption |
| Rack with Switches |
0.9 kilowatts |
| Base MMU |
1.5 kilowatts |
| Expansion MMU |
1.1 kilowatts |
| Base SSU |
2.3 kilowatts |
| Expansion SSU |
2.0 kilowatts |
| |
| Peak Heat Dissipation |
| Rack with Switches |
3,073 BTU |
| Base MMU |
5,122 BTU |
| Expansion MMU |
3,756 BTU |
| Base SSU |
7,853 BTU |
| Expansion SSU |
6,829 BTU |
|
|